Cheap Precision Non-Contact Tonometer for Ophthalmic Use

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Tonometer
Still deciding? Get samples of US$ 1380/Piece
Request Sample
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
1001~2000 square meters
  • Cheap Precision Non-Contact Tonometer for Ophthalmic Use
  • Cheap Precision Non-Contact Tonometer for Ophthalmic Use
  • Cheap Precision Non-Contact Tonometer for Ophthalmic Use
  • Cheap Precision Non-Contact Tonometer for Ophthalmic Use
  • Cheap Precision Non-Contact Tonometer for Ophthalmic Use
  • Cheap Precision Non-Contact Tonometer for Ophthalmic Use
Find Similar Products

Basic Info.

Model NO.
FA800
Precision
1mmhg
Name
Tonometer Ophthalmic
Shelf Life
1years
Max Probe Speed
0.2m/S
Transport Package
Metal Box
Specification
portable
Trademark
FA
Origin
Shanghai
HS Code
9018500000
Production Capacity
99999

Product Description

Cheap Precision Non-Contact Tonometer for Ophthalmic UseCheap Precision Non-Contact Tonometer for Ophthalmic Use

 


FA-800 Portable Tonometer Rebound


 

FA-800 Portable Tonometer Rebound

 

Fuan(Shanghai) Enterprise Development Co., Ltd. is proud to present the FA-800 Portable Tonometer Rebound. This cutting-edge hand-held device is specifically designed to provide accurate and efficient intraocular pressure measurement.

 

Features:

 

  • Portable and hand-held design for easy use and convenience.

  • Utilizes rebound technology for precise intraocular pressure measurement.

  • Provides accurate results quickly, saving time for both patients and healthcare professionals.

  • Designed with advanced technology to ensure reliable and consistent measurements.


  •  
 

Benefits:

 

  • Allows for on-the-go intraocular pressure measurement, making it ideal for mobile healthcare professionals.

  • Reduces the need for bulky and expensive equipment, providing a cost-effective solution.

  • Enables efficient and accurate diagnosis of conditions such as glaucoma.

  • Enhances patient comfort with its non-invasive measurement technique.


  •  
 

Experience the convenience and accuracy of the FA-800 Portable Tonometer Rebound from Fuan(Shanghai) Enterprise Development Co., Ltd. Order yours today!



 

Product Features:

 

The Ultimate Portable Measurement Device

 

The hand-held and portable design of our product makes it incredibly convenient to use. Whether you're in a clinic or on the go, you can easily carry it with you. Plus, it utilizes low voltage technology, ensuring safe and reliable measurements every time.

 

With a small contact area between the probe and the patient's cornea, our product ensures accurate and precise measurements. This means you can trust the results it provides. And with a short measuring time, you can quickly and efficiently conduct examinations, saving you valuable time.

 

One of the best things about our product is that it doesn't cause any unsuitable reactions during the measurement process. This ensures a comfortable experience for the patient and accurate readings for the healthcare professional.

 

Additionally, our product features an automatic magnetizing and withdrawing needle, making it incredibly easy to use. This user-friendly design enhances the overall convenience and efficiency of the device.

 

Trust Fuan(Shanghai) Enterprise Development Co., Ltd. for a high-quality product that meets all your needs.

Product Benefits:

 

FA-800 Portable Tonometer Rebound

 

The FA-800 Portable Tonometer Rebound, developed by Fuan(Shanghai) Enterprise Development Co., Ltd., is a cutting-edge device that offers a range of benefits for healthcare professionals and patients alike.

 

  • Accurate and reliable intraocular pressure measurements

  • Convenient and easy-to-use design

  • Minimizes patient discomfort with a small contact area

  • Reduces examination time, improving workflow efficiency

  • No adverse reactions, ensuring patient safety and comfort

  • Automatic needle functionality simplifies the measurement process


  •  
 

With its advanced technology and superior performance, the FA-800 Portable Tonometer Rebound is a must-have for healthcare professionals seeking accurate and efficient intraocular pressure measurements. Its convenient design and automatic needle functionality make it easy to use, while the small contact area minimizes patient discomfort. The device also reduces examination time, improving workflow efficiency for healthcare professionals.

 

Order your FA-800 Portable Tonometer Rebound today and experience the benefits of this state-of-the-art device!

               

Weight:

300g

Measuring range:

3mmHg~70mmHg

Measuring error:

 

±1.5mmHg(3mmHg≤Intraocular pressure measured≤25mmHg);

±2.5mmHg (25mmHg≤Intraocular pressure measured≤70mmHg)



 


FA800 Rebound Tonometer



 

FA800 Rebound Tonometer



 

Advantages:

 

  • The measurement results are accurate and consistent, proven correct through clinical studies.

  • Painless and anxiety-free, eliminating the need for local anesthesia.

  • Safe for repeated measurements without harming the eyes of adults and children.

  • Easy self-measurement without requiring assistance from others.

  • Features the most advanced lateral LCD design, allowing operators to control the distance between the probe and the cornea and read values on the display.

  • Compact and portable, allowing for continuous monitoring of ocular pressures anywhere without environmental restrictions.

  • Disposable probes to avoid cross-infection.

  • Can be used in an upright or lying gesture, accommodating patients with mobility issues.

  • Wireless data printing (requires another photocopier).

  • Built-in storage function to store up to ten sets of data for review or printing.

  • Time and date settings for easy review.

  • Safe and energy-efficient with AA battery usage.

  • Uses integrated circuits for stable and long-lasting performance.


  •  


 

Applicability:

 

Used in tonometry tests by ophthalmologists, optometrists, general physicians, and professional health advisors.

 

Ideal for patients with dementia, mobility problems, and children in measuring corneal edema, opacity, or uneven corneal surface.

 

Handy for glaucoma patients to measure ocular pressure at home.



 

Usages:

 

  1. Turn on the tonometer and install the probe.

  2. Move the machine close to the eyes and adjust the distance.

  3. Gently press the button to obtain single measurement values and average values.

  4. Short measuring time, only seconds. Reduces check time for glaucoma.

  5. Capable of storing ocular data for up to ten patients.


  6.  


 

The Working Mechanism of FA800 Rebound Tonometer

 

The FA800 Rebound Tonometer, also known as an impact tonometer, adopts an innovative sensing rebound technology. The probe is magnetized when inserted into the tonometer, generating N/S poles. A transient current in the solenoids of the device produces a transient magnetic field, causing the magnetized probe to move towards the cornea at 0.2m/s (homopolar repulsion principle). The probe bounces on the anterior surface of the cornea, slowing down and rebounding. As the ocular pressure increases, the deceleration of the probe increases, and the duration of the impact decreases. The electrical control switch monitors the solenoid voltage caused by the rebound of the magnetized probes, and the electronic signal processor and microsensor calculate the deceleration of the probe after impacting the cornea. Finally, the integrated information is converted into ocular pressure readings.

 

The FA800 Rebound Tonometer is an electric measuring type pressure gauge that converts pressure into voltage or current signals through the physical characteristics of the metal. It can obtain measurement data within 0.1 seconds.



 

Company Name:

 

Fuan(Shanghai) Enterprise Development Co., Ltd.




             Cheap Precision Non-Contact Tonometer for Ophthalmic UseCheap Precision Non-Contact Tonometer for Ophthalmic UseCheap Precision Non-Contact Tonometer for Ophthalmic UseCheap Precision Non-Contact Tonometer for Ophthalmic Use
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier