• Affordable Handheld Tonometer with High Precision
  • Affordable Handheld Tonometer with High Precision
  • Affordable Handheld Tonometer with High Precision
  • Affordable Handheld Tonometer with High Precision
  • Affordable Handheld Tonometer with High Precision
  • Affordable Handheld Tonometer with High Precision

Affordable Handheld Tonometer with High Precision

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Tonometer
Certification: CE
Precision: 1mmhg
Name: Tonometer Ophthalmic
Shelf Life: 1years
Samples:
US$ 1380/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
FA800
Max Probe Speed
0.2m/S
Transport Package
Metal Box
Specification
portable
Trademark
FA
Origin
Shanghai
HS Code
9018500000
Production Capacity
99999

Product Description

Affordable Handheld Tonometer with High PrecisionAffordable Handheld Tonometer with High Precision


FA-800 Portable Tonometer Rebound


 

FA-800 Portable Tonometer Rebound

 

Fuan(Shanghai) Enterprise Development Co., Ltd. presents the FA-800 Portable Tonometer Rebound, a cutting-edge hand-held device designed for accurate and efficient intraocular pressure measurement.

 

Product Features:

 

  • Portable and Hand-held: The FA-800 is a compact and lightweight tonometer that can be easily carried and used anywhere.

  • Accurate Measurements: Utilizing rebound technology, this device provides precise intraocular pressure readings, ensuring reliable results.

  • Efficient Operation: With its user-friendly interface, the FA-800 allows for quick and hassle-free measurements, saving time for both patients and healthcare professionals.


  •  
 

Benefits:

 

  • Convenience: The portable design of the FA-800 allows for on-the-go intraocular pressure monitoring, making it ideal for home use or during travel.

  • Reliability: The rebound technology ensures accurate measurements, providing healthcare professionals with dependable data for diagnosis and treatment.

  • Time-saving: The efficient operation of the FA-800 reduces the time required for intraocular pressure measurements, enhancing patient experience and optimizing workflow in clinics.


  •  
 

Experience the cutting-edge technology of the FA-800 Portable Tonometer Rebound, brought to you by Fuan(Shanghai) Enterprise Development Co., Ltd.



 

Product Features:

 

Product Description

 

Introducing the innovative hand-held and portable design of our latest product from Fuan(Shanghai) Enterprise Development Co., Ltd. This device is specifically designed for convenient use, allowing you to easily carry it wherever you go.

 

With our low voltage technology, you can rest assured that your measurements will be safe and reliable. The small contact area between the probe and the patient's cornea ensures accurate readings without causing any discomfort.

 

Our device also boasts a short measuring time, allowing for quick and efficient examinations. Say goodbye to long waiting times and hello to faster diagnoses.

 

Furthermore, you can trust that our device will not cause any unsuitable reactions during the measurement process. We prioritize your safety and comfort above all else.

 

For added convenience, our device features an automatic magnetizing and withdrawing needle. This makes it incredibly easy to use, even for those with limited experience.

Product Benefits:




FA-800 Portable Tonometer Rebound



 

FA-800 Portable Tonometer Rebound



 

The FA-800 Portable Tonometer Rebound, developed by Fuan(Shanghai) Enterprise Development Co., Ltd., is a cutting-edge device that offers numerous benefits to healthcare professionals and patients alike.



 

Key Features:

 

  • Accurate and reliable intraocular pressure measurements

  • Convenient and easy-to-use design for healthcare professionals

  • Minimizes patient discomfort with a small contact area

  • Reduces examination time, improving workflow efficiency

  • No adverse reactions, ensuring patient safety and comfort

  • Automatic needle functionality simplifies the measurement process


  •  


 

Experience the advanced technology and superior performance of the FA-800 Portable Tonometer Rebound from Fuan(Shanghai) Enterprise Development Co., Ltd. Order yours today!




 

Weight:

300g

Measuring range:

3mmHg~70mmHg

Measuring error:

 

±1.5mmHg(3mmHg≤Intraocular pressure measured≤25mmHg);

±2.5mmHg (25mmHg≤Intraocular pressure measured≤70mmHg)




FA800 Rebound Tonometer


 

FA800 Rebound Tonometer

 

Advantages:

 

  • The measurement results are accurate and consistent, proven correct through clinical studies.

  • Painless and anxiety-free, eliminating the need for local anesthesia.

  • Safe for repeated measurements without harming the eyes of adults and children.

  • Easy self-measurement without requiring assistance from others.

  • Features the most advanced lateral LCD design, allowing operators to control the distance between the probe and the cornea and read values on the display.

  • Compact and portable, allowing for continuous monitoring of ocular pressures anywhere without environmental restrictions.

  • Disposable probes to avoid cross-infection.

  • Can be used in an upright or lying gesture, accommodating patients with mobility issues.

  • Wireless data printing (requires another photocopier).

  • Built-in storage function to store up to ten sets of data for review or printing.

  • Time and date settings for easy review.

  • Safe and energy-efficient with AA battery usage.

  • Uses integrated circuits for stable and long-lasting performance.


  •  
 

Applicability:

 

Used in tonometry tests by ophthalmologists, optometrists, general physicians, and professional health advisors.

 

Ideal for patients with dementia, mobility problems, and children in measuring corneal edema, opacity, or uneven corneal surface.

 

Handy for glaucoma patients to measure ocular pressure at home.

 

Usages:

 

  1. Turn on the tonometer and install the probe.

  2. Move the machine close to the eyes and adjust the distance.

  3. Gently press the button to obtain single measurement values and average values.

  4. Short measuring time, only seconds. Reduces check time for glaucoma.

  5. Capable of storing ocular data for up to ten patients.


  6.  
 

The Working Mechanism of FA800 Rebound Tonometer

 

The FA800 Rebound Tonometer, also known as an impact tonometer, adopts an innovative sensing rebound technology. The probe is magnetized when inserted into the tonometer, generating N/S poles. A transient current in the solenoids of the device produces a transient magnetic field, causing the magnetized probe to move towards the cornea at 0.2m/s (homopolar repulsion principle). The probe bounces on the anterior surface of the cornea, slowing down and rebounding. As the ocular pressure increases, the deceleration of the probe increases, and the duration of the impact decreases. The electrical control switch monitors the solenoid voltage caused by the rebound of the magnetized probes, and the electronic signal processor and microsensor calculate the deceleration of the probe after impacting the cornea. Finally, the integrated information is converted into ocular pressure readings.

 

The FA800 Rebound Tonometer is an electric measuring type pressure gauge that converts pressure into voltage or current signals through the physical characteristics of the metal. It can obtain measurement data within 0.1 seconds.

 

Company Name:

 

Fuan(Shanghai) Enterprise Development Co., Ltd.



Affordable Handheld Tonometer with High PrecisionAffordable Handheld Tonometer with High PrecisionAffordable Handheld Tonometer with High PrecisionAffordable Handheld Tonometer with High Precision
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
5000000 RMB
Plant Area
1001~2000 square meters