Rebound Tonometer Ophthalmic Device with 1mmhg Precision

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Tonometer
Still deciding? Get samples of US$ 1380/Piece
Request Sample
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
1001~2000 square meters
  • Rebound Tonometer Ophthalmic Device with 1mmhg Precision
  • Rebound Tonometer Ophthalmic Device with 1mmhg Precision
  • Rebound Tonometer Ophthalmic Device with 1mmhg Precision
  • Rebound Tonometer Ophthalmic Device with 1mmhg Precision
  • Rebound Tonometer Ophthalmic Device with 1mmhg Precision
  • Rebound Tonometer Ophthalmic Device with 1mmhg Precision
Find Similar Products

Basic Info.

Model NO.
FA800
Certification
CE
Precision
1mmhg
Name
Tonometer Ophthalmic
Shelf Life
1years
Max Probe Speed
0.2m/S
Transport Package
Metal Box
Specification
portable
Trademark
FA
Origin
Shanghai
HS Code
9018500000
Production Capacity
99999

Product Description

Rebound Tonometer Ophthalmic Device with 1mmhg PrecisionRebound Tonometer Ophthalmic Device with 1mmhg Precision


FA-800 Portable Tonometer Rebound


 

FA-800 Portable Tonometer Rebound

 

Fuan(Shanghai) Enterprise Development Co., Ltd. is proud to introduce the FA-800 Portable Tonometer Rebound. This state-of-the-art handheld device is specifically designed to provide accurate and efficient measurement of intraocular pressure.

 

Key Features:

 

  • Accuracy: The FA-800 utilizes advanced technology to ensure precise measurement of intraocular pressure, providing reliable results for eye care professionals.

  • Portability: With its compact and lightweight design, this tonometer can be easily carried and used in various clinical settings, making it convenient for on-the-go professionals.

  • Efficiency: The handheld nature of the FA-800 allows for quick and efficient measurements, saving valuable time for both the practitioner and the patient.


  •  
 

Benefits:

 

  • Enhanced Patient Comfort: The non-contact rebound measurement method of the FA-800 eliminates the need for anesthesia or eye drops, ensuring a comfortable experience for patients.

  • Improved Hygiene: The device's disposable probe covers minimize the risk of cross-contamination, promoting a hygienic and safe examination environment.

  • Easy Data Management: The FA-800 is equipped with user-friendly software that enables seamless data transfer and analysis, simplifying record-keeping and enhancing workflow efficiency.


  •  
 

Invest in the FA-800 Portable Tonometer Rebound from Fuan(Shanghai) Enterprise Development Co., Ltd. and experience the cutting-edge technology that revolutionizes intraocular pressure measurement.



 

Product Features:

 

Product Description

 

Introducing the innovative hand-held and portable design from Fuan(Shanghai) Enterprise Development Co., Ltd. Our cutting-edge device is designed with your convenience in mind, allowing you to take measurements anytime, anywhere.

 

With our low voltage technology, you can trust that our device provides safe and reliable measurements, ensuring your peace of mind. The small contact area between the probe and the patient's cornea guarantees accurate readings without any discomfort.

 

Our device is designed to save you time, with a short measuring time that allows for quick and efficient examinations. Say goodbye to long waiting times and hello to efficient patient care.

 

Rest assured, our device ensures no unsuitable reactions during the measurement process, providing a seamless experience for both you and your patients. You can trust in the accuracy and reliability of our device.

 

For ease of use, our device features an automatic magnetizing and withdrawing needle, making it incredibly user-friendly. No more hassle or inconvenience during measurements.

 

Experience the convenience, safety, and efficiency of our device from Fuan(Shanghai) Enterprise Development Co., Ltd. Order yours today and revolutionize your examination process.

Product Benefits:




FA-800 Portable Tonometer Rebound


 

FA-800 Portable Tonometer Rebound

 

The FA-800 Portable Tonometer Rebound, developed by Fuan(Shanghai) Enterprise Development Co., Ltd., is designed to meet the reading habits of English-speaking natives. This innovative tonometer offers a range of features and benefits:

 

  • Accurate and reliable intraocular pressure measurements

  • Convenient and easy-to-use design for healthcare professionals

  • Minimizes patient discomfort with a small contact area

  • Reduces examination time, improving workflow efficiency

  • No adverse reactions, ensuring patient safety and comfort

  • Automatic needle functionality simplifies the measurement process


  •  
 

Experience the advanced technology and superior performance of the FA-800 Portable Tonometer Rebound from Fuan(Shanghai) Enterprise Development Co., Ltd. Order yours today!



 

Weight:

300g

Measuring range:

3mmHg~70mmHg

Measuring error:

 

±1.5mmHg(3mmHg≤Intraocular pressure measured≤25mmHg);

±2.5mmHg (25mmHg≤Intraocular pressure measured≤70mmHg)




FA800 Rebound Tonometer


 

FA800 Rebound Tonometer

 

Advantages:

 

  • The measurement results are accurate and consistent, proven correct through clinical studies.

  • Painless and anxiety-free, eliminating the need for local anesthesia.

  • Safe for repeated measurements without harming the eyes of adults and children.

  • Easy self-measurement without requiring assistance from others.

  • Features the most advanced lateral LCD design, allowing operators to control the distance between the probe and the cornea and read values on the display.

  • Compact and portable, allowing for continuous monitoring of ocular pressures anywhere without environmental restrictions.

  • Disposable probes to avoid cross-infection.

  • Can be used in an upright or lying gesture, accommodating patients with mobility issues.

  • Wireless data printing (requires another photocopier).

  • Built-in storage function to store up to ten sets of data for review or printing.

  • Time and date settings for easy review.

  • Safe and energy-efficient with AA battery usage.

  • Uses integrated circuits for stable and long-lasting performance.


  •  
 

Applicability:

 

Used in tonometry tests by ophthalmologists, optometrists, general physicians, and professional health advisors.

 

Ideal for patients with dementia, mobility problems, and children in measuring corneal edema, opacity, or uneven corneal surface.

 

Handy for glaucoma patients to measure ocular pressure at home.

 

Usages:

 

  1. Turn on the tonometer and install the probe.

  2. Move the machine close to the eyes and adjust the distance.

  3. Gently press the button to obtain single measurement values and average values.

  4. Short measuring time, only seconds. Reduces check time for glaucoma.

  5. Capable of storing ocular data for up to ten patients.


  6.  
 

The Working Mechanism of FA800 Rebound Tonometer

 

The FA800 Rebound Tonometer, also known as an impact tonometer, adopts an innovative sensing rebound technology. The probe is magnetized when inserted into the tonometer, generating N/S poles. A transient current in the solenoids of the device produces a transient magnetic field, causing the magnetized probe to move towards the cornea at 0.2m/s (homopolar repulsion principle). The probe bounces on the anterior surface of the cornea, slowing down and rebounding. As the ocular pressure increases, the deceleration of the probe increases, and the duration of the impact decreases. The electrical control switch monitors the solenoid voltage caused by the rebound of the magnetized probes, and the electronic signal processor and microsensor calculate the deceleration of the probe after impacting the cornea. Finally, the integrated information is converted into ocular pressure readings.

 

The FA800 Rebound Tonometer is an electric measuring type pressure gauge that converts pressure into voltage or current signals through the physical characteristics of the metal. It can obtain measurement data within 0.1 seconds.

 

Company Name: Fuan(Shanghai) Enterprise Development Co., Ltd.



Rebound Tonometer Ophthalmic Device with 1mmhg PrecisionRebound Tonometer Ophthalmic Device with 1mmhg PrecisionRebound Tonometer Ophthalmic Device with 1mmhg PrecisionRebound Tonometer Ophthalmic Device with 1mmhg Precision
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier